Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Injury ; 55(4): 111486, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447478

RESUMO

OBJECTIVE: The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures. METHODS: A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens. RESULTS: Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037). CONCLUSIONS: Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability. LEVEL OF EVIDENCE: not applicable (biomechanical).


Assuntos
Fraturas Distais do Úmero , Fraturas do Úmero , Humanos , Fraturas do Úmero/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Úmero/cirurgia , Placas Ósseas , Parafusos Ósseos , Cadáver
2.
J Orthop ; 52: 102-106, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38440410

RESUMO

Purpose: Olecranon fractures are classified using the commonly accepted Mayo classification. Its reliability has been analyzed by means of radiographs. A CT scan is often obtained due to joint involvement. Purpose of this study was to evaluate the intra- and interobserver reliability of the Mayo classification based on CT examination. Methods: Radiographic and CT images of 20 olecranon fractures were classified by four surgeons at two time points 30 days apart. Intra- and interobserver reliability were assessed using kappa coefficients. Results: Mean intraobserver reliability between X-rays was substantial and between CTs almost perfect (0.76 and 0.82, respectively). Mean interobserver reliability was fair for X-rays and moderate for CTs (0.32 and 0.44, respectively). Conclusion: Despite the more detailed imaging compared with radiography only moderate interobserver reliability was found for the classification of olecranon fractures based on CT imaging. This might lead to inconsistent fracture classification in both scientific and clinical setting.

3.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329521

RESUMO

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Assuntos
Articulação do Cotovelo , Nervo Ulnar , Masculino , Adulto , Humanos , Feminino , Nervo Ulnar/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Cotovelo/inervação , Tomografia Computadorizada por Raios X
4.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978963

RESUMO

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Humanos , Polegar , Ligamento Colateral Ulnar/diagnóstico por imagem , Ligamento Colateral Ulnar/lesões , Ligamentos Colaterais/lesões , Fenômenos Biomecânicos , Articulação Metacarpofalângica
5.
Pediatr Emerg Care ; 40(1): 2-5, 2024 Jan 01.
Artigo em Alemão, Inglês | MEDLINE | ID: mdl-36898049

RESUMO

OBJECTIVES: Buckle fractures of the distal forearm are a common fracture entity in children treated conservatively. Diagnostics primarily include radiographs in 2 planes. Inadequate images may occur in the mostly very young patients. Therefore, additional lateral radiographs are often obtained to assess a possible angular tilt. The aim of this study is to investigate whether a strictly lateral x-ray image has an influence on fracture management. METHODS: Seventy-three children with buckle fractures of the distal forearm were included in this retrospective analysis. All cases were analyzed by quality of radiographs, necessity to obtain an additional lateral radiograph, and what influence on fracture management resulted. Follow-up was performed 2 to 4 weeks after immobilization. RESULTS: Thirty-five girls and 38 boys with a mean age of 7.16 years were included; 40 had fractured right and 33 had fractured left arms, respectively. Isolated distal radius fractures occurred in 48 cases, isolated distal ulna fractures in 6 cases, and both bones in 19 cases. Initial radiographic images were evaluated as inadequate in 25 cases. In each of those cases, an additional lateral image was obtained by fluoroscopy without resulting in an alternated fracture management protocol, which was chosen conservatively in each case and resulted in excellent clinical outcome at follow-up examination. CONCLUSIONS: Based on our results, the acquisition of additional lateral radiographs seems to be unnecessary in the diagnostic procedure of buckle fractures of the distal forearm, in case a possible palmar or dorsal angulation cannot be entirely assessed on the initial set of radiographs. An additional lateral image had no influence on fracture management, which was chosen conservatively in every case and led to excellent clinical results.Level of evidence: level III.


Assuntos
Fraturas Múltiplas , Fraturas do Rádio , Fraturas da Ulna , Masculino , Criança , Feminino , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/terapia , Antebraço , Estudos Retrospectivos , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/terapia , Punho
6.
Artigo em Inglês | MEDLINE | ID: mdl-37652214

RESUMO

BACKGROUND: To reduce hardware-related complications in coracoid graft fixation to the anterior aspect of the glenoid, a metal-free Latarjet technique was recently introduced. The aim of this study was to compare the primary stability of a classic Latarjet procedure with 2 metal screws to a novel metal-free, all-suture cerclage method. It is hypothesized that fixation of the coracoid graft with 2 malleolar screws will provide higher primary stability compared with an all-suture cerclage technique. METHODS: This biomechanical in vitro study was conducted on 12 fresh-frozen cadaveric shoulders (6 matched pairs) with a mean donor age of 80 years (range, 67-89 years). Coracoid graft fixation was performed using a recently introduced all-suture cerclage technique (group A) or a classic Latarjet technique with two 4.5-mm malleolar screws (group B). The conjoint tendon was loaded with a static force of 10 N to simulate the sling effect. Graft loading with a probe head consisted of 6 ascending load levels (10-50 N, 10-100 N, 10-150 N, 10-200 N, 10-250 N, and 10-300 N) with 100 cycles each at 1 Hz. Relative motion of the bone graft to the glenoid was measured using an optic 3-dimensional system. RESULTS: While loading the conjoint tendon with 10 N, no difference in mean displacement of the bone-graft was found between both groups (P = .144). During cyclic loading, a significant difference in relative displacement for both groups was already detected in load level 1 (group A: 2398.8 µm vs. group B: 125.7 µm; P = .024), and this trend continued with the following load levels (P < .05). DISCUSSION AND CONCLUSION: The study demonstrated that the innovative metal-free, all-suture cerclage fixation technique results in higher micromotion than the classic coracoid graft fixation with 2 malleolar screws. According to the present biomechanical investigation, shoulders treated with a metal-free all-suture cerclage technique might need adapted rehabilitation protocols to protect the construct and allow for graft healing.

7.
J Biomech ; 158: 111766, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37633217

RESUMO

Elbow trauma is often accompanied by a loss of independence in daily self-care activities, negatively affecting patients' quality of life. Finite element models can help gaining profound knowledge about native human joint mechanics, which is crucial to adequately restore joint functionality after severe injuries. Therefore, a finite element model of the elbow is required that includes both the radio-capitellar and ulno-trochlear joint and is subjected to loads realistic for activities of daily living. Since no such model has been published, we aim to fill this gap. For comparison, 8 intact cadaveric elbows were subjected to loads of up to 1000 N, after they were placed in an extended position. At each load step, the displacement of the proximal humerus relative to the distal base plate was measured with optical tracking markers and the joint pressure was measured with a pressure mapping sensor. Analogously, eight finite element models were created based on subject-specific CT scans of the corresponding elbow specimens. The CT scans were registered to the positions of tantalum beads in the experiment. The optically measured displacements were applied as boundary conditions. We demonstrated that the workflow can predict the experimental contact pressure distribution with a moderate correlation, the experimental peak pressures in the correct joints and the experimental stiffness with moderate to excellent correlation. The predictions of peak pressure magnitude, contact area and load share on the radius require improvement by precise representation of the cartilage geometry and soft tissues in the model, and proper initial contact in the experiment.


Assuntos
Atividades Cotidianas , Cotovelo , Humanos , Análise de Elementos Finitos , Qualidade de Vida , Fenômenos Biomecânicos
8.
Arch Orthop Trauma Surg ; 143(10): 6243-6249, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37421514

RESUMO

PURPOSE: Postoperative soft tissue swelling is a significant factor influencing outcomes after elbow surgery. It can crucially affect important parameters such as postoperative mobilization, pain, and subsequently the range of motion (ROM) of the affected limb. Furthermore, lymphedema is considered a significant risk factor for numerous postoperative complications. Manual lymphatic drainage is nowadays part of the standardized post-treatment concept, basing on the concept of activating the lymphatic tissue to absorb stagnated fluid from the tissue into the lymphatic system. This prospective study aims to investigate the influence of technical device-assisted negative pressure therapy (NP) on early functional outcomes after elbow surgery. NP was therefore compared to manual lymphatic drainage (MLD). Is a technical device-based NP suitable for treatment of lymphedema after elbow surgery? METHODS: A total of 50 consecutive patients undergoing elbow surgery were enrolled. The patients were randomized into 2 groups. 25 participants per group were either treated by conventional MLD or NP. The primary outcome parameter was defined as the circumference of the affected limb in cm postoperative up to seven days postoperatively. The secondary outcome parameter was a subjective perception of pain (measured via visual analogue scale, VAS). All parameters were measured on each day of postoperative inpatient care. RESULTS AND CONCLUSION: NP showed an overall equivalent influence compared to MLD in reducing upper limb swelling after surgery. Moreover, the application of NP showed a significant decrease in overall pain perception compared to manual lymphatic drainage on days 2, 4 and 5 after surgery (p < 0.05). CONCLUSION: Our findings show that NP could be a useful supplementary device in clinical routine treating postoperative swelling after elbow surgery. Its application is easy, effective and comfortable for the patient. Especially due to the shortage of healthcare workers and physical therapists, there is a need for supportive measures which NP could be.


Assuntos
Linfedema , Drenagem Linfática Manual , Humanos , Drenagem Linfática Manual/efeitos adversos , Estudos Prospectivos , Cotovelo , Edema/etiologia , Edema/terapia , Linfedema/complicações , Dor , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 143(8): 5027-5034, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37042984

RESUMO

INTRODUCTION: Nailing of the proximal humerus is an established method for the treatment of proximal humerus fractures. Choice of the correct length for potentially four proximal locking screws is essential for postoperative outcome. Due to positioning of the patient, intraoperative determination of the correct length of the anteroposterior (AP) screw with the x-ray beam is particularly challenging even for experienced surgeons. We hypothesized that there would be a correlation between the projected lengths of the different proximal locking screws and therefore the length of the AP-screw could be determined based on the three lateromedial (LM) screws. MATERIALS AND METHODS: In this retrospective study (level of evidence: III) CT-scans of shoulders of 289 patients were 3D reconstructed with the program Horos. Using the manufacturer Stryker's instructions, the four proximal locking screws of the T2 Humeral Nail system were reproduced in the 3D reconstructed shoulders. The length of the AP-screw was correlated with the lengths of the LM-screws by Linear Regression and Multiple Linear Regression. RESULTS: The results of this study showed that the lengths of proximal locking screws in proximal humeral nailing correlated significantly with each other. Based on the given data, a formula could be established to calculate the length of the AP-screw based on the lengths of the LM-screws with a probability of 76.5%. CONCLUSIONS: This study was able to show that the length of the AP-screw could be determined from the intraoperatively measured lengths of the LM-screws. As our findings base on measurements performed in CT scans, clinical studies are needed to support our data.


Assuntos
Úmero , Fraturas do Ombro , Humanos , Estudos Retrospectivos , Úmero/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Tomografia Computadorizada por Raios X , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Placas Ósseas
10.
Injury ; 2023 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-37100696

RESUMO

INTRODUCTION: Varus posteromedial rotational injury mechanisms lead to fractures of the coronoids process' anteromedial facet. As these fractures are often unstable, rapid fracture treatment is vital to prevent progressive osteoarthritis. MATERIALS AND METHODS: Twelve patients with a fracture of the anteromedial facet treated surgically were enrolled in the study. Computed tomography images were used to classify the fractures according to the system by O'Driscoll et al. Clinical follow-up included each patient's medical record, surgical treatment algorithm, all complications encountered during the follow-up period, Disabilities of the arm, shoulder, and hand score, subjective elbow value, and pain. RESULTS: A total of 8 men (66.7%) and 4 women (33.3%) were treated surgically and followed-up after a mean period of 45 ± 23 months. The mean DASH score was 11.9 ± 12.9 points. One patient complained of transient neuropathy in the innervation area of the ulnar nerve, however, this existed already pre-operatively and resolved after less than three months. CONCLUSIONS: The presented patient cohort shows that AMF fracture of the coronoid process are unstable lesions according to the bony instability and the frequently ruptured collateral ligament complexes which need to be addressed. The MCL seems to be affected more frequently than previously appreciated. LEVEL OF EVIDENCE: Level IV; Case Series; Treatment Study.

11.
J Hand Surg Eur Vol ; 48(8): 768-772, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37005740

RESUMO

Studies on graft reconstruction techniques for ruptured thumb metacarpophalangeal (MCP) ulnar collateral ligaments (UCL) do not consider the variety of MCP joint morphology. Optimal reconstruction method for flat MCP joints is therefore unclear. Twenty-four fresh-frozen, human thumbs were tested for flexion, extension and valgus stability of the MCP joint. After resection of the UCL, four reconstruction methods, differing in the metacarpal origin and phalangeal attachment, were performed on each specimen, which were then tested again in the same way. Specimens were grouped as 'round' or 'flat' depending on morphometric parameters and group differences were analysed. In flat joints, only the non-anatomical Glickel reconstruction and a modified Fairhurst reconstruction maintained normal mobility and stability. In round joints, only the Glickel reconstruction maintained normal mobility and stability. The original Fairhurst method and a modification with the origin palmar in the metacarpus were disadvantageous in both flat and round joints.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Humanos , Ligamento Colateral Ulnar/cirurgia , Polegar/cirurgia , Ligamentos Colaterais/cirurgia , Amplitude de Movimento Articular , Articulação Metacarpofalângica/cirurgia
12.
Surg Radiol Anat ; 45(5): 571-580, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36892617

RESUMO

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.


Assuntos
Articulação do Cotovelo , Úmero , Adulto , Humanos , Reprodutibilidade dos Testes , Úmero/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Cotovelo/diagnóstico por imagem , Radiografia
13.
Arch Orthop Trauma Surg ; 143(5): 2383-2393, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35482109

RESUMO

INTRODUCTION: Stiffness after elbow injuries can severely limit daily life. If adequate conservative treatment does not result in satisfactory improvement of elbow function, surgical intervention should be considered. Whether an open or arthroscopic procedure is preferable is still a topic of debate and a systematic review of functional outcomes is lacking. MATERIALS AND METHODS: We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and EMBASE, for studies published between 2013 and 2021. Primary objective was to compare open and arthroscopic arthrolysis' functional outcomes, respectively, especially ROM and MEPS, as well as the accompanied complications. The PRISMA guidelines were applied. RESULTS: 27 studies comprising 1666 patients were included. 1059 patients (63.6%) were treated with open arthrolysis, and 607 patients (36.4%) were treated with arthroscopic arthrolysis. The results presented indicate satisfactory outcomes in open and arthroscopic arthrolysis with regard to functional outcome parameters. Treatment success, defined as excellent or good results according to the Mayo Elbow Performance Score, among the patients treated with an open procedure was 88.8%; 6.3% required revision whereas 18.1% had complications without the need for revision surgery. Within the cohort of arthroscopically treated patients, treatment success was 91.8%. Revisions and complications without further surgical intervention were significantly less frequent than in the open cohort, at 1.6% and 9.1%, respectively. CONCLUSIONS: Both open and arthroscopic arthrolysis provide good to excellent functional outcomes. Since the number of complications and revision increases with the invasiveness of the treatment, an arthroscopic procedure might be favored if feasible by indication. The role of forearm rotation and the use of a hinged external fixator remains of interest. STUDY DESIGN: Level IV; Systematic review.


Assuntos
Articulação do Cotovelo , Artropatias , Procedimentos Ortopédicos , Humanos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Artropatias/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
14.
Arch Orthop Trauma Surg ; 143(5): 2467-2474, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35579703

RESUMO

INTRODUCTION: In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS: Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS: In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION: A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Manguito Rotador/cirurgia , Fraturas do Ombro/cirurgia , Ombro , Úmero , Cadáver
15.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35064826

RESUMO

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Cotovelo , Instabilidade Articular/cirurgia , Articulação do Cotovelo/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Cadáver , Suturas , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões
16.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35635575

RESUMO

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Assuntos
Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Idoso , Parafusos Ósseos , Fraturas do Ombro/cirurgia , Úmero/cirurgia , Placas Ósseas , Cadáver , Fenômenos Biomecânicos
17.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35731264

RESUMO

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Assuntos
Articulação do Cotovelo , Fraturas Cominutivas , Fraturas do Úmero , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/métodos , Úmero , Redução Aberta/métodos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
18.
Arch Orthop Trauma Surg ; 143(7): 4111-4116, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197491

RESUMO

PURPOSE: The optimal screw placement in arthroscopically assisted fixation of radial head fractures is still an issue and no guiding methods have been evaluated in the recent literature. The study hypothesis was that using a "reference k-wire" percutaneously inserted in and parallel to the radiocapitellar joint would enable to achieve a trajectory more parallel to the radial head articular surface as compared to a free-hand k-wire placement. METHODS: Arthroscopically assisted placement of a k-wire in the radial head was performed in seven fresh-frozen human cadaver specimens by three surgeons. Three different techniques were evaluated: freehand drilling (technique A), placement using a "reference" k-wire in the radiocapitellar joint as a reference without (technique B), and with the AO parallel k-wire guide (technique C). Radiographs from all procedures were obtained and the inclination angle "α" between the k-wire and the articular surface of the radial head was measured and compared among the techniques. RESULTS: Angles of 84 radiographs were obtained and showed a mean α angle of 30.1° ± 13° for technique A, 5.7° ± 4.5° for technique B, and 5.4° ± 3.7° for technique C. The angle α was significantly higher with technique A as compared to B (p < 0.0001) and C (p < 0.0001). There was no difference between methods B and C (n.s.). No difference was observed among the surgeons for all three methods (p = 0.66). CONCLUSION: With the use of an additional "reference" k-wire placed in the radiocapitellar joint, the guiding k-wire for screw drilling can be placed almost parallel to the radial head joint line with limited variability and a good reproducibility during arthroscopically assisted radial head fracture fixation. CLINICAL RELEVANCE: The here-presented method of an additional, percutaneous introduced "reference" k-wire is easily applicable and helpful to achieve parallel screw placement during arthroscopically assisted radial head fracture fixation. LEVEL OF EVIDENCE: IV, biomechanical cadaver study.


Assuntos
Articulação do Cotovelo , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Reprodutibilidade dos Testes , Parafusos Ósseos , Fios Ortopédicos , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Cotovelo/cirurgia , Cadáver
19.
Clin Biomech (Bristol, Avon) ; 101: 105867, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36584578

RESUMO

BACKGROUND: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. METHODS: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal-reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. FINDINGS: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. INTERPRETATION: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Prótese do Joelho , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Artrite Infecciosa/cirurgia , Reoperação/métodos
20.
Arch Orthop Trauma Surg ; 143(7): 4229-4237, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36512058

RESUMO

INTRODUCTION: The aim of the present study was to develop a technical process to reproducibly generate terrible triad injuries (TTI) in fresh-frozen human cadaveric specimens, while leaving the skin intact. Such "pre-fractured" specimens, used for scientific analysis and for surgical education, might help to improve current treatment, which is complex and prone to complications. MATERIALS AND METHODS: To induce the desired fractures, a custom-made fracturing unit was used to apply an axial force on the extended cadaveric elbow specimens, with the forearm pronated and under valgus load. To simulate the valgus load, a pneumatic cylinder was developed to apply valgus stress to the joint by an additional force vector from the lateral side of the joint. RESULTS: The success rate of TTI induction was 92.3% (12/13). Of the 12 radial head fractures, 3 (25%) were classified Mason type II and 9 (75%) Mason type III. The coronoid fractures were grouped in tip subtype 2 (5 fractures, 41.7%), anteromedial facet (AMF) subtype 2 (4 fractures, 33.3%), AMF subtype 3 (1 fracture, 8.3%) and basal subtype 1 (2 fractures, 16.7%). CONCLUSIONS: The present study provides an instrument for successful and reproducible production of dislocation fracture patterns with their typical accompanying soft tissue lesions. The methodology might be applied on a broad basis to be able to perform biomechanical studies regarding primary stability of fixation concepts for TTI and to educate surgeons in a fairly realistic scenario with the surgical treatment of TTI.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo , Luxações Articulares , Fraturas do Rádio , Fraturas da Ulna , Humanos , Luxações Articulares/cirurgia , Fraturas do Rádio/cirurgia , Articulação do Cotovelo/cirurgia , Cadáver , Fraturas da Ulna/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...